Home | People | Facilities | Capabilities | Publications | Links | Contact |
|
Two-Phase Flow
The laboratory has a $1M two-phase test package that has been flown on
reduced gravity aircraft numerous times. This facility is able to
produce monitored single phase flow streams that are mixed to produce a
desired two-phase/single component flow test condition using refrigerant
based working fluid. The two-phase flow is then directed through two
test sections, which have been used for visualization, hardware
evaluation, and sensor validation. The use of a unique two-phase pump
eliminates the need for a heater and produces highly accurate test
conditions for two-phase investigations. Data is taken from numerous
instruments using high speed digital data acquisition system as well as
video and high speed (1000 fps) digital imagery. A recent addition to
the two-phase flow facility is the Large Diameter Test Package shown
during a recent reduced gravity flight. The air/water system utilizes a
phase separator to recycle the liquid and is able to produce all liquid
to all gas flow through test sections on the order of two inches in
diameter. The ITP has extensive experience in the development of
two-phase flow systems for testing under reduced gravity conditions.
|